Abstract

SUMMARY

Blood-culture broths showing macroscopic or radiometric evidence of growth of gram-negative bacilli were examined by a rapid automated bacterial identification system. A differential centrifugation technique was developed to prepare suitable inocula. The identification results obtained were confirmed by the API 20E method, with single colonies of the strains isolated 24 h later. Of 90 organisms tested, seven did not give the same identification by the two systems. With the rapid automated technique a presumptive identification of gram-negative bacilli can be made 24 h earlier than by more conventional methods.

Loading

Article metrics loading...

/content/journal/jmm/10.1099/00222615-21-3-215
1986-05-01
2024-05-03
Loading full text...

Full text loading...

/deliver/fulltext/jmm/21/3/medmicro-21-3-215.html?itemId=/content/journal/jmm/10.1099/00222615-21-3-215&mimeType=html&fmt=ahah

References

  1. Blazevic D J, Trombley C M, Lund M E. 1976; Inoculation of API 20E from positive blood cultures. Journal of Clinical Microbiology 4:522–523
    [Google Scholar]
  2. Cowan ST. 1974 Cowan and Steel’s Manual for the Identification of Medical Bacteria, 2nd edn.. Cambridge University Press; Cambridge:
    [Google Scholar]
  3. Furtado G L, Medeiros A A. 1982; Rapid biochemical identification of Gram-negative bacilli from blood cultures using API 20E strips. American Journal of Clinical Pathology 78:356–357
    [Google Scholar]
  4. Kovacs N. 1956; Identification of Pseudomonas pyocyanea by the oxidase reaction. Nature 178:703
    [Google Scholar]
  5. Malloy P J, Ducate M J, Schreckenberger P C. 1983; Comparison of four rapid methods for identification of Enterobacteria- ceae from blood cultures. Journal of Clinical Microbiology 17:493–499
    [Google Scholar]
  6. Mounier M, Denis F. 1983; Four-hour direct identification of Enterobacteriaceae in blood cultures. European Journal of Clinical Microbiology 2:593–595
    [Google Scholar]
  7. Murray P R, Gauthier A, Niles A. 1984; Evaluation of the Quantum II and Rapid E identification systems. Journal of Clinical Microbiology 20:509–514
    [Google Scholar]
  8. Stevens M, Henrichsen C, Smith M. 1986; A collaborative evaluation of a rapid, semi-automated identification system for gram-negative bacilli: the Quantum II BID. Journal of Medical Microbiology 21:145–150
    [Google Scholar]
  9. Wasilauskas B L, Ellner P D. 1971; Presumptive identification of bacteria from blood cultures in four hours. Journal of Infectious Diseases 124:499–504
    [Google Scholar]
http://instance.metastore.ingenta.com/content/journal/jmm/10.1099/00222615-21-3-215
Loading
/content/journal/jmm/10.1099/00222615-21-3-215
Loading

Data & Media loading...

This is a required field
Please enter a valid email address
Approval was a Success
Invalid data
An Error Occurred
Approval was partially successful, following selected items could not be processed due to error