The use of gene probes, immunoassays and tissue culture for the detection of toxin in Vibrio cholerae non-O1 Said, Bengü and Scotland, Sylvia M. and Rowe, B.,, 40, 31-36 (1994), doi = https://doi.org/10.1099/00222615-40-1-31, publicationName = Microbiology Society, issn = 0022-2615, abstract= Summary. Vibrio cholerae non-O1 strains were screened for the presence of cholera enterotoxin (CT) genes by means of digoxigenin-labelled polynucleotide CTA and CTB probes. In-vitro production of CT was investigated by the Y1 mouse adrenal cell assay, enzyme-linked immunosorbent assay (ELISA) and a commercial, reversed passive latex agglutination (RPLA) kit. Only two (0·25%) of 790 strains tested gave positive results with the CTA and CTB probes. The production of other bacterial cytotoxin(s) made it impossible to use the characteristic cell-rounding effect on Y1 cells for the detection of CT. CT production by the probe-positive strains was confirmed by the immunoassays. Two hundred and fifty-two of the 788 probe-negative strains were tested by both cell assay and immunoassays. Of these, 90% produced cytotoxin(s) in the cell assay. In addition, 37% gave positive results in CT-ELISA, but negative results with LT-ELISA and VET-RPLA. These results indicate the presumed presence of a toxin in V. cholerae non-O1 that is able to bind GM1 and react with antisera to CT, but which is not identical to CT., language=, type=