1887

Abstract

We considered the application of MALDI-TOF mass spectrometry for BSL-3 bacterial diagnostics, with a focus on the biosafety of live-culture direct-colony testing and the stability of stored extracts. Biosafety level 2 (BSL-2) bacterial species were used as surrogates for BSL-3 high-consequence pathogens in all live-culture MALDI-TOF experiments. Viable BSL-2 bacteria were isolated from MALDI-TOF mass spectrometry target plates after ‘direct-colony’ and ‘on-plate’ extraction testing, suggesting that the matrix chemicals alone cannot be considered sufficient to inactivate bacterial culture and spores in all samples. Sampling of the instrument interior after direct-colony analysis did not recover viable organisms, suggesting that any potential risks to the laboratory technician are associated with preparation of the MALDI-TOF target plate before or after testing. Secondly, a long-term stability study (3 years) of stored MALDI-TOF extracts showed that match scores can decrease below the threshold for reliable species identification (<1.7), which has implications for proficiency test panel item storage and distribution.

Loading

Article metrics loading...

/content/journal/jmm/10.1099/jmm.0.000695
2018-03-01
2024-04-25
Loading full text...

Full text loading...

/deliver/fulltext/jmm/67/3/341.html?itemId=/content/journal/jmm/10.1099/jmm.0.000695&mimeType=html&fmt=ahah

References

  1. Dingle TC, Butler-Wu SM. MALDI-TOF mass spectrometry for microorganism identification. Clin Lab Med 2013; 33:589–609 [View Article][PubMed]
    [Google Scholar]
  2. Karger A. Current developments to use linear MALDI-TOF spectra for the identification and typing of bacteria and the characterization of other cells/organisms related to infectious diseases. Proteomics Clin Appl 2016; 10:982–993 [View Article][PubMed]
    [Google Scholar]
  3. Patel R. MALDI-TOF MS for the diagnosis of infectious diseases. Clin Chem 2015; 61:100–111 [View Article]
    [Google Scholar]
  4. Alatoom AA, Cunningham SA, Ihde SM, Mandrekar J, Patel R. Comparison of direct colony method versus extraction method for identification of gram-positive cocci by use of Bruker Biotyper matrix-assisted laser desorption ionization-time of flight mass spectrometry. J Clin Microbiol 2011; 49:2868–2873 [View Article][PubMed]
    [Google Scholar]
  5. Fournier R, Wallet F, Grandbastien B, Dubreuil L, Courcol R et al. Chemical extraction versus direct smear for MALDI-TOF mass spectrometry identification of anaerobic bacteria. Anaerobe 2012; 3:294–297 [View Article][PubMed]
    [Google Scholar]
  6. Lasch P, Grunow R, Antonation K, Weller SA, Jacob D. Inactivation techniques for MALDI-TOF MS analysis of highly pathogenic bacteria – a critical review. Trends Anal Chem 2016; 85:112–119 [View Article]
    [Google Scholar]
  7. Keller PM, Bruderer V, Muller F. Restricted identification of clinical pathogens categorized as biothreats by MALDI-TOF mass spectrometry. J Clin Microbiol 2016; 54:816 [Crossref]
    [Google Scholar]
  8. Dingle TC, Butler-Wu SM, Abbott AN. Accidental exposure to Burkholderia pseudomallei in the laboratory in the era of matrix-assisted laser desorption ionization-time of flight mass spectrometry. J Clin Microbiol 2014; 52:3490–3491 [View Article][PubMed]
    [Google Scholar]
  9. Centers for Disease Control and Prevention Report on the potential exposure to anthrax; 2014
  10. Cunningham SA, Patel R. Importance of using Bruker's security-relevant library for Biotyper identification of Burkholderia pseudomallei, Brucella species, and Francisella tularensis . J Clin Microbiol 2013; 51:1639–1640 [View Article][PubMed]
    [Google Scholar]
  11. Lasch P, Wahab T, Weil S, Pályi B, Tomaso H et al. Identification of highly pathogenic microorganisms by matrix-assisted laser desorption ionization-time of flight mass spectrometry: Results of an interlaboratory ring trial. J Clin Microbiol 2015; 53:2632–2640 [View Article][PubMed]
    [Google Scholar]
  12. Tracz DM, Antonation KS, Corbett CR. Verification of a matrix-assisted laser desorption ionization-time of flight mass spectrometry method for diagnostic identification of high-consequence bacterial pathogens. J Clin Microbiol 2016; 54:764–767 [View Article][PubMed]
    [Google Scholar]
  13. New York City Department of Health and Mental Hygiene Alert #15: Imported brucellosis: Recent laboratory exposures requiring prophylaxis and long-term follow up; 2015
  14. Cunningham SA, Patel R. Standard matrix-assisted laser desorption ionization-time of flight mass spectrometry reagents may inactivate potentially hazardous bacteria. J Clin Microbiol 2015; 53:2788–2789 [View Article][PubMed]
    [Google Scholar]
  15. Tracz DM, Tyler AD, Cunningham I, Antonation KS, Corbett CR. Custom database development and biomarker discovery methods for MALDI-TOF mass spectrometry-based identification of high-consequence bacterial pathogens. J Microbiol Methods 2017; 134:54–57 [View Article]
    [Google Scholar]
  16. Drevinek M, Dresler J, Klimentova J, Pisa L, Hubalek M. Evaluation of sample preparation methods for MALDI-TOF MS identification of highly dangerous bacteria. Lett Appl Microbiol 2012; 55:40–46 [View Article][PubMed]
    [Google Scholar]
  17. Lasch P, Nattermann H, Erhard M, Stämmler M, Grunow R et al. MALDI-TOF mass spectrometry compatible inactivation method for highly pathogenic microbial cells and spores. Anal Chem 2008; 80:2026–2034 [View Article][PubMed]
    [Google Scholar]
  18. ISO/IEC 17043 Conformity assessment – General requirements for proficiency testing. 2010;ISO/IEC 17043:2010(E)
http://instance.metastore.ingenta.com/content/journal/jmm/10.1099/jmm.0.000695
Loading
/content/journal/jmm/10.1099/jmm.0.000695
Loading

Data & Media loading...

This is a required field
Please enter a valid email address
Approval was a Success
Invalid data
An Error Occurred
Approval was partially successful, following selected items could not be processed due to error